Running engineering simulations in the cloud while using existing licenses presents challenges due to the hardware dependency of on-premise license servers, which are typically behind corporate firewalls. Traditional solutions involve setting up a VPN connection, but this requires significant time and corporate IT involvement. An alternative is using a reverse SSH tunnel, which avoids modifying firewalls and allows secure, encrypted communication between cloud instances and a license proxy server. This method offers flexibility, as the connection can be controlled and terminated by the customer without affecting the corporate firewall. A specific example involves configuring FlexLM, where ports are mapped through an SSH command to facilitate communication between the cloud and the license server. This approach allows engineers to manage licenses efficiently while maintaining security, with Rescale providing the necessary setup and support for seamless integration.